Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
BMC Infect Dis ; 21(1): 9, 2021 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-33407180

RESUMEN

BACKGROUND: To determine the prevalence of enteric infections in Aboriginal children aged 0-2 years using conventional and molecular diagnostic techniques and to explore associations between the presence of pathogens and child growth. METHODS: Cross-sectional analysis of Aboriginal children (n = 62) residing in a remote community in Northern Australia, conducted from July 24th - October 30th 2017. Stool samples were analysed for organisms by microscopy (directly in the field and following fixation and storage in sodium-acetate formalin), and by qualitative PCR for viruses, bacteria and parasites and serology for Strongyloides-specific IgG. Child growth (height and weight) was measured and z scores calculated according to WHO growth standards. RESULTS: Nearly 60% of children had evidence for at least one enteric pathogen in their stool (37/62). The highest burden of infection was with adenovirus/sapovirus (22.9%), followed by astrovirus (9.8%) and Cryptosporidium hominis/parvum (8.2%). Non-pathogenic organisms were detected in 22.5% of children. Ten percent of children had diarrhea at the time of stool collection. Infection with two or more pathogens was negatively associated with height for age z scores (- 1.34, 95% CI - 2.61 to - 0.07), as was carriage of the non-pathogen Blastocystis hominis (- 2.05, 95% CI - 3.55 to - 0.54). CONCLUSIONS: Infants and toddlers living in this remote Northern Australian Aboriginal community had a high burden of enteric pathogens and non-pathogens. The association between carriage of pathogens/non-pathogens with impaired child growth in the critical first 1000 days of life has implications for healthy child growth and development and warrants further investigation. These findings have relevance for many other First Nations Communities that face many of the same challenges with regard to poverty, infections, and malnutrition.


Asunto(s)
Infecciones por Adenovirus Humanos/epidemiología , Adenovirus Humanos/genética , Infecciones por Astroviridae/epidemiología , Infecciones por Caliciviridae/epidemiología , Criptosporidiosis/epidemiología , Cryptosporidium/genética , Gastroenteritis/epidemiología , Mamastrovirus/genética , Sapovirus/genética , Infecciones por Adenovirus Humanos/virología , Adenovirus Humanos/aislamiento & purificación , Animales , Infecciones por Astroviridae/virología , Australia/epidemiología , Infecciones por Caliciviridae/virología , Preescolar , Estudios Transversales , Criptosporidiosis/parasitología , Cryptosporidium/aislamiento & purificación , Diarrea/epidemiología , Diarrea/parasitología , Diarrea/virología , Heces/parasitología , Heces/virología , Femenino , Gastroenteritis/parasitología , Gastroenteritis/virología , Humanos , Lactante , Recién Nacido , Masculino , Mamastrovirus/aislamiento & purificación , Nativos de Hawái y Otras Islas del Pacífico , Reacción en Cadena de la Polimerasa/métodos , Prevalencia , Sapovirus/aislamiento & purificación
2.
J Med Microbiol ; 69(9): 1169-1178, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32755529

RESUMEN

Introduction. The SARS-CoV-2 pandemic of 2020 has resulted in unparalleled requirements for RNA extraction kits and enzymes required for virus detection, leading to global shortages. This has necessitated the exploration of alternative diagnostic options to alleviate supply chain issues.Aim. To establish and validate a reverse transcription loop-mediated isothermal amplification (RT- LAMP) assay for the detection of SARS-CoV-2 from nasopharyngeal swabs.Methodology. We used a commercial RT-LAMP mastermix from OptiGene in combination with a primer set designed to detect the CDC N1 region of the SARS-CoV-2 nucleocapsid (N) gene. A single-tube, single-step fluorescence assay was implemented whereby 1 µl of universal transport medium (UTM) directly from a nasopharyngeal swab could be used as template, bypassing the requirement for RNA purification. Amplification and detection could be conducted in any thermocycler capable of holding 65 °C for 30 min and measure fluorescence in the FAM channel at 1 min intervals.Results. Assay evaluation by assessment of 157 clinical specimens previously screened by E-gene RT-qPCR revealed assay sensitivity and specificity of 87 and 100%, respectively. Results were fast, with an average time-to-positive (Tp) for 93 clinical samples of 14 min (sd±7 min). Using dilutions of SARS-CoV-2 virus spiked into UTM, we also evaluated assay performance against FDA guidelines for implementation of emergency-use diagnostics and established a limit-of-detection of 54 Tissue Culture Infectious Dose 50 per ml (TCID50 ml-1), with satisfactory assay sensitivity and specificity. A comparison of 20 clinical specimens between four laboratories showed excellent interlaboratory concordance; performing equally well on three different, commonly used thermocyclers, pointing to the robustness of the assay.Conclusion. With a simplified workflow, The N1 gene Single Tube Optigene LAMP assay (N1-STOP-LAMP) is a powerful, scalable option for specific and rapid detection of SARS-CoV-2 and an additional resource in the diagnostic armamentarium against COVID-19.


Asunto(s)
Infecciones por Coronavirus/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/métodos , Neumonía Viral/diagnóstico , Betacoronavirus , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Técnicas de Laboratorio Clínico , Humanos , Técnicas de Diagnóstico Molecular/métodos , Nasofaringe/virología , Pandemias , ARN Viral , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transcripción Reversa , SARS-CoV-2 , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...